one.2.two Warning Labels Warning Labels Which means Make sure you cautiously read this handbook just before use machine. The next labels undoubtedly are a. Do not position the product over a sloped area. In any other case the accessible in the event the process system may perhaps slide, resulting in private injury or the system is effective Along with the cellular malfunction.
Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat detail login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.
Take note: Around the monitor, the brightness adjustment comes in advance of contrast. Soon after readjusting the monitor’s contrast and brightness, alter all preset and peripheral configurations.
This guide may well referring to facts safeguarded by copyright or patents and won't Express any license under the patent rights or copyright of Mindray, or of Many others. Website page 9: Statement
Click Agree and Proceed to accept cookies and go straight to the location or click on More Information to see specific descriptions of the types of cookies and choose no matter whether to just accept specified cookies when on the internet site.
Mindray’s new era of black & white ultrasound technique, DP-50 Professional, is provided with advanced imaging systems making it possible for deeper penetration and faster graphic acquisition with increased resolution.
S. have to present the Section using an e-mail deal with if they've got one particular. The email messages offered could be utilized for Formal interaction While using the licensee. Nevertheless email addresses are general public file. If you do not wish to produce a private tackle, you should offer the Section having an e-mail address which may be created accessible to the public. You should see our Chapter 455 website page to determine When you are impacted by this alteration.
Uncover greater diagnostic facts as a result of prolonged watch of your anatomical framework on all convex probes.
Analyzing clients in now’s demanding environment necessitates progressive technological know-how that permits clinicians to create brief and assured diagnoses. The flexibility in the DP-50 expands your medical utility though helping to strengthen client treatment.
five.two.three Geometric positioning precision Longitudinal geometric positioning precision Exam Stage: Do adjustments as just how in testing the maximum depth. Document the gap by 20mm Just about every phase on the longitudinal targets line using the measurement caliper; Choose the value with the greatest error (to 20mm), determine the accuracy using the formulation below The measurement caliper must be positioned for the higher edge of the goal, Be aware:... Website page 79 Transverse geometric positioning accuracy Test Step: Cover the scan surface on the phantom with drinking water or couple gel, gently contact the probe Using the scan surface Regulate the depth, building the transverse targets to be shown while in the picture. Adjust the main target place to get posited beside the transverse targets (the normal isn't clear) Change parameters like achieve, TGC, creating each transverse targets being Obviously exhibited. Webpage eighty 5.five.2.4 Blackout Area Take a look at Stage: Address the scan surface area of your phantom with drinking water or pair gel, gently Speak to the probe Using the scan floor Regulate the depth at a decreased value, and set the main focus at the closest place to the scan surface area. Lessen the worth of parameters like AP, Obtain right until the background sound just can be witnessed. Website page eighty one: Application Up grade And Upkeep
Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.
Observe: Prior to uploading the log, be certain the ultrasound program has been connected to network, normally, the system may possibly alert “couldn't connect to server” The server (smtp.
Be aware: Just before inserting the connector in to the probe port, inspect the connector pin. When the pin is bent, usually do not make use of the probe right up until it has been inspected / fixed / replaced. Putting in Peripherals To the designs of the supported peripherals, be sure to seek advice from “2.
Just after replacing the CPU module, critical file has to be created Again based on the new MAC handle and created into HDD with the equipment. Or else, the configuration function in the products will likely be missing. After eliminating the CPU module, Clear away panhead screws with washers (twelve M3X6) fastened on the main device box, you may take from the board. Page 118 Determine eight-29 Disassemble the User interface Assembly (1) Hold the higher fringe of user interface assembly, and open up the user interface. Determine 8-30 Disassemble the User interface Assembly (two) Just after eradicating a person countersunk head self-tapping screw PT3X10 preset over the user interface and get out the plug from the keyboard Dp50rb login and the leading device connecting cables, you can eliminate the control panel assembly.
A smart new form, Improved mobility and practical operation make DP-50 well suited for all clinical configurations.